Korean Journal of Clinical Dental Hygiene (Korean J Clin Dent Hyg)

Open Access, Peer-reviewed
Indexed in Korea Ciation Index

pISSN 2287-9641
eISSN 2465-7743

RESEARCH ARTICLE

Microbiological Investigation of Reusing Disposable Saliva Ejectors

Department of Dental Hygiene, College of Software and Digital Healthcare Convergence, Yonsei University, Wonju, 26493, Korea
†These authors contributed equally as a first author.

*Corresponding Author: Jung Yun Kang, E-mail: hannahkang@yonsei.ac.kr

Volume 12, Number 2, Pages 129–136, June 2024.
Korean J Clin Dent Hyg 2024;12(2):129–136. https://doi.org/10.12972/kjcdh.20240013
Received on April 08, 2024, Revised on April 24, 2024, Accepted on May 09, 2024, Published on June 30, 2024.
Copyright © 2024 by Korean Society of Infection Control and Prevention in Dental Hygiene.
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License(http://creativecommons.org/licenses/by-nc/4.0/).

Abstract

Objective: Dental instruments are often designed for single use; however, some dental clinics resort to reusing instruments, including saliva ejectors. In this study, we aimed to investigate and compare various disinfection and sterilization methods for contaminated disposable salivary ejectors. Methods: Saliva ejectors contaminated with Streptococcus mutans were divided into five groups: negative control, positive control, cleaning, disinfection, and sterilization. Surface contamination and microbial culture tests were conducted using the adenosine triphosphate (ATP) test and colony-forming units (CFUs) counting, respectively. One-way ANOVA was used to assess the differences among groups. Results: There were no significant differences among the cleaning, disinfection, and sterilization groups based on immediate ATP test. However, CFU counts were significantly higher in the cleaning and disinfection groups compared to negative control group, while no microbial growth was observed in the sterilization group. Conclusions: This study demonstrated that saliva ejectors harbor bacteria capable of growth, even after cleaning with a toothbrush or disinfectant. Autoclaving proved to be the most effective sterilization method, eliminating microbial growth, and allowing for microbiological reuse. Future studies involving diverse microorganisms and different types of contaminants are recommended.
Keywords

Dental instrument, Disinfection, Infection control, Saliva ejector, Sterilization

Section