RESEARCH ARTICLE
Comparison of Calculus Removal Efficiency and Working Posture Between Ultrasonic and Manual Scalers
Han-Na Kim
1†
, Tae-Lim Yoon
2†
, Ji-Hyun Min
3
1Department of Dental Hygiene, College of Software and Digital Healthcare Convergence, Yonsei University, 1 Yonseidae-gil, Wonju 26493, Korea
2Department of Physical Therapy, College of Health & Medical Sciences, Cheongju University, Cheongju, 28503, Korea
3Department of Dental Hygiene, College of Health & Medical Sciences, Cheongju University, Cheongju, 28503, Korea
†These two authors contributed equally to the manuscript.
Corresponding Author: Ji-Hyun Min, E-mail: jhmin@cju.ac.kr
Volume 13, Number 3, Pages 165–173, September 2025.
Korean J Clin Dent Hyg 2025;13(3):165–173. https://doi.org/10.12972/kjcdh.2025.13.3.4
Received on June 30, 2025, Revised on August 03, 2025, Accepted on August 06, 2025, Published on September 30, 2025.
Copyright © 2025 by Korean Society of Infection Control and Prevention in Dental Hygiene.
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License(http://creativecommons.org/licenses/by-nc/4.0/).
Abstract
Objective: In this study, we compared calculus removal efficiency and dental hygienists’ joint angles when using ultrasonic and manual scalers to assess clinical and ergonomic differences. Methods: Thirty-seven dental hygienists performed scaling on two artificial calculus-coated dentiform models: one with an ultrasonic scaler and the other with a manual scaler. We quantified calculus removal using an image analysis software. We measured the joint angles at the cervical spine, lumbar spine, elbow, and wrist using inertial sensors. We used paired- sample t-tests for statistical analysis. Results: Ultrasonic scalers yielded significantly higher calculus removal across all regions (p<0.001). The lumbar flexion angle was significantly smaller when using the ultrasonic scaler(103.75 °) compared to that when using the manual scaler(108.39 °)(p=0.010), and the elbow flexion angle was closer to neutral(73.97 °; p=0.010). Wrist flexion/extension also decreased with the ultrasonic scaler(p=0.035), indicating a reduced musculoskeletal burden. Conclusions: Ultrasonic scalers improve calculus removal efficiency and promote a more ergonomic posture by reducing lumbar and wrist strain. Our findings support the use of ultrasonic devices for clinical effectiveness and dental hygienists’ musculoskeletal safety.
Keywords
Dental hygienists, Dental scaling, Ergonomics, Musculoskeletal system, Posture